<- Materials & Physical PropertiesImpact & Tear / 41BCY-30A

Pendulum Impact Tester for Films

Measure pendulum impact resistance of films, foils and thin flexible materials.

A pendulum impact tester for plastic films, sheets, laminates, metal foil and similar flexible materials.

Reference unit price / AvailabilityUSD 4,500 per system / In stock
BCY-30A Pendulum Impact Tester for Films
01 / Application

Workflow and key features

The BCY-30A releases a controlled pendulum against the mounted specimen and measures the energy absorbed during failure. Quantified impact resistance helps packaging and material teams compare formulations, gauges and process conditions.

  • Controlled pendulum energy provides repeatable impact comparison
  • Suitable for film, sheet, laminate and foil structures
  • Automatic result capture reduces manual reading error
  • Supports material development, incoming inspection and routine QC
  • Pendulum capacity and specimen fixture are selected for the expected strength
02 / Public technical data

Reference configuration

Published values describe the referenced standard configuration. The formal quotation confirms the selected range, fixtures, utilities, method edition and supplied documentation.

Impact energy
1 J, 2 J or 3 J standard
Resolution
0.001 J
Impact heads
25.4 mm and 12.7 mm diameter; custom sizes available
Specimen diameters
60 mm and 89 mm
Specimen opening
100 x 100 mm or 100 mm diameter
Machine dimensions
455 x 255 x 480 mm
Operating environment
15-35 deg C; RH <=80%, non-condensing
Electrical supply
220 V, 50 Hz
Test-method referencesWorkflow references, not a certification claim2 references

These references identify workflows described for this model. The formal quotation confirms the exact edition, fixtures, software, accessories and verification documents supplied for the selected configuration.

  • GB/T 8809-2015
  • ASTM D3420
Typical materials
  • Plastic films
  • Composite films
  • Metal foils
  • Thin sheet materials
Send with your inquiry
  • Material structure and thickness
  • Sample dimensions
  • Required test method
  • Expected force, pressure or barrier range
Configuration boundary

The quoted configuration remains the controlling specification.

Published values describe the referenced standard configuration. The formal quotation confirms the selected range, fixtures, utilities, method edition and supplied documentation. Delivery scope, warranty, lead time, calibration evidence and overseas service are stated in the formal offer.

Request formal configuration
Next in Materials & Physical PropertiesSLD-1000ZElectronic Tear Tester->
WAAsk an engineer