<- Pharmaceutical & Medical TestingMasks & Filtration / 31YLC-01A

Mask Airflow Resistance Tester

Measure airflow resistance across masks and protective filter articles.

An airflow-resistance tester for surgical, disposable medical, KN95 and daily protective masks.

Reference unit price / AvailabilityUSD 5,000 per system / In stock
YLC-01A Mask Airflow Resistance Tester
01 / Application

Workflow and key features

The YLC-01A passes a defined airflow through the mounted mask or material and measures the resulting pressure difference. The result quantifies breathing comfort and helps manufacturers control filter-media and mask-construction consistency.

  • Quantifies airflow resistance under a controlled flow condition
  • Supports surgical, disposable, protective and daily-use mask formats
  • Helps balance filtration performance against wearer breathing comfort
  • Suitable for manufacturers, quality laboratories and R&D organizations
  • Flow, fixture and result units are selected against the required method
02 / Public technical data

Reference configuration

Published values describe the referenced standard configuration. The formal quotation confirms the selected range, fixtures, utilities, method edition and supplied documentation.

Flow range
1-10 L/min
Pressure range
+/-1 kPa
Timing resolution
0.01 s
Test medium
Air
Control
Embedded system
Required air supply
0.7-1.0 MPa through a 6 mm polyurethane tube
Net weight
12 kg
Electrical supply
220 VAC, 50 Hz
Test-method referencesWorkflow references, not a certification claim1 references

These references identify workflows described for this model. The formal quotation confirms the exact edition, fixtures, software, accessories and verification documents supplied for the selected configuration.

  • YY/T 0969-2013
Typical materials
  • Medical masks
  • Disposable masks
  • Protective masks
  • Filter assemblies
Send with your inquiry
  • Device or protective-article type
  • Required test method
  • Challenge conditions or expected force range
  • Sample dimensions and quantity
Configuration boundary

The quoted configuration remains the controlling specification.

Published values describe the referenced standard configuration. The formal quotation confirms the selected range, fixtures, utilities, method edition and supplied documentation. Delivery scope, warranty, lead time, calibration evidence and overseas service are stated in the formal offer.

Request formal configuration
Next in Pharmaceutical & Medical TestingHXY-01Mask Breathing Resistance Tester->