<- Pharmaceutical & Medical TestingNeedle Mechanics / 36ZRX-01A

Medical Needle Tubing Toughness Tester

Evaluate repeated bending toughness of medical needle tubing.

A medical needle-tubing toughness tester for evaluating resistance to repeated bending without fracture.

Reference unit price / AvailabilityUSD 4,000 per system / In stock
ZRX-01A Medical Needle Tubing Toughness Tester
01 / Application

Workflow and key features

The ZRX-01A bends configured stainless-steel needle tubing through the defined angle and cycle sequence. The test identifies brittle tubing or process variation that could create a fracture risk during clinical use.

  • Controlled bend angle and cycle sequence improve repeatability
  • Targets toughness rather than static stiffness alone
  • Applicable to injection needles and compatible medical-device tubing
  • Supports production QC, supplier qualification and failure investigation
  • Mandrel, spacing and needle dimensions are matched to the method
02 / Public technical data

Reference configuration

Published values describe the referenced standard configuration. The formal quotation confirms the selected range, fixtures, utilities, method edition and supplied documentation.

Tube-wall categories
Regular, thin-wall or extra-thin-wall
Nominal size
0.5-4.5 mm
Test frequency
0.5 Hz
Bending angles
15, 20 or 25 degrees
Bending distance
6-95 mm
Accuracy
+/-0.1 mm
Test cycles
20 bidirectional loading cycles
Machine dimensions
400 x 270 x 300 mm (L x W x H)
Test-method referencesWorkflow references, not a certification claim1 references

These references identify workflows described for this model. The formal quotation confirms the exact edition, fixtures, software, accessories and verification documents supplied for the selected configuration.

  • GB 18457-2015
Typical materials
  • Injection-needle tubing
  • Rigid stainless-steel tubing
  • Medical needle components
  • Prepared tubing samples
Send with your inquiry
  • Device or protective-article type
  • Required test method
  • Challenge conditions or expected force range
  • Sample dimensions and quantity
Configuration boundary

The quoted configuration remains the controlling specification.

Published values describe the referenced standard configuration. The formal quotation confirms the selected range, fixtures, utilities, method edition and supplied documentation. Delivery scope, warranty, lead time, calibration evidence and overseas service are stated in the formal offer.

Request formal configuration
Next in Pharmaceutical & Medical TestingYYB-01Pharmaceutical Packaging Force Tester->
WAAsk an engineer