<- Glass Container TestingAmpoule Strength / 22ABP-01

Ampoule Breaking Force Tester

Quantify the force required to separate an ampoule neck.

An automatic force tester for measuring the break force of ampoule necks and compatible brittle cosmetic products.

Reference unit price / AvailabilityUSD 4,500 per system / In stock
ABP-01 Ampoule Breaking Force Tester
01 / Application

Workflow and key features

The ABP-01 applies a controlled displacement to the defined break point and records the peak force. Quantified results help control ampoule opening performance so the neck is neither dangerously hard to open nor mechanically weak.

  • Controlled speed and displacement improve break-force repeatability
  • Standard fixture covers common ampoule capacities
  • Automatic peak-force capture replaces subjective manual assessment
  • Also supports configured lipstick, brow-pencil and similar break tests
  • Data output supports production quality control and complaint investigation
02 / Public technical data

Reference configuration

Published values describe the referenced standard configuration. The formal quotation confirms the selected range, fixtures, utilities, method edition and supplied documentation.

Force range
10-500 N
Accuracy class
Class 0.5
Travel
500 mm
Test speed
1-500 mm/min, stepless
Displacement accuracy
1%
Ampoule capacity
1-25 mL with the standard fixture
Machine dimensions
550 x 450 x 1040 mm
Net weight
65 kg
Electrical supply
AC 220 V, 50 Hz
Test-method referencesWorkflow references, not a certification claim2 references

These references identify workflows described for this model. The formal quotation confirms the exact edition, fixtures, software, accessories and verification documents supplied for the selected configuration.

  • GB/T 2637
  • YBB00332002-2015
Typical materials
  • Pharmaceutical ampoules
  • Prepared break-point samples
  • Selected cosmetic sticks
  • Application-specific brittle components
Send with your inquiry
  • Container type and drawing
  • Sample dimensions and quantity
  • Required test method
  • Target load, pressure or thermal profile
Configuration boundary

The quoted configuration remains the controlling specification.

Published values describe the referenced standard configuration. The formal quotation confirms the selected range, fixtures, utilities, method edition and supplied documentation. Delivery scope, warranty, lead time, calibration evidence and overseas service are stated in the formal offer.

Request formal configuration
Next in Glass Container TestingNNY-01AGlass Bottle Internal Pressure Tester->
WAAsk an engineer