<- Pharmaceutical & Medical TestingMasks & Filtration / 30CTY-01A

Synthetic Blood Penetration Tester

Evaluate resistance to synthetic-blood penetration under defined challenge conditions.

A synthetic-blood penetration tester for medical masks and other coated protective materials under defined challenge pressure.

Reference unit price / AvailabilityUSD 6,600 per system / In stock

Included reference configuration: One CTY-01A synthetic-blood penetration tester for the published mask-testing workflow. Consumable test liquid and external compressed-air equipment are excluded.

Delivery basis & quotation terms

Budgetary reference for one system, FCA Jinan, China (Incoterms 2020). International freight, insurance, import duties/taxes, overseas on-site service and optional upgrades are excluded. The itemized written quotation confirms the final configuration and total. Existing project quotations retain their own terms and validity.

Price reviewed 2026-09-22
CTY-01A Synthetic Blood Penetration Tester
01 / Application

Workflow and key features

The CTY-01A projects a specified volume of synthetic blood at the specimen and supports visual evaluation of penetration. Controlled pressure and geometry help compare barrier performance relevant to medical protective products.

  • Defined synthetic-blood challenge replaces uncontrolled splash tests
  • Adjustable challenge pressure supports different mask classifications
  • Applicable to medical masks and configured coated protective materials
  • Consistent target distance and specimen mounting improve repeatability
  • Supports product development, type testing and routine quality checks
02 / Public technical data

Reference configuration

Published values describe the referenced standard configuration. The formal quotation confirms the selected range, fixtures, utilities, method edition and supplied documentation.

Required air supply
0.7-1.0 MPa through a 6 mm polyurethane tube
Pressure vessel adjustment
0-40 kPa
Dispensing-valve adjustment
0-40 kPa
Timing resolution
0.01 s
Test medium
Air
Control
Microcomputer
Net weight
12 kg
Electrical supply
220 VAC, 50 Hz
Test-method referencesWorkflow references, not a certification claim4 references

These references identify workflows described for this model. The formal quotation confirms the exact edition, fixtures, software, accessories and verification documents supplied for the selected configuration.

  • YY/T 0969-2013
  • GB 19083-2010
  • YY/T 0691-2008
  • ISO 22609
Typical materials
  • Medical masks
  • Protective face coverings
  • Coated fabrics
  • Barrier materials
Send with your inquiry
  • Device or protective-article type
  • Required test method
  • Challenge conditions or expected force range
  • Sample dimensions and quantity
Configuration boundary

The quoted configuration remains the controlling specification.

Published values describe the referenced standard configuration. The formal quotation confirms the selected range, fixtures, utilities, method edition and supplied documentation. Delivery scope, warranty, lead time, calibration evidence and overseas service are stated in the formal offer.

Request formal configuration
Next in Pharmaceutical & Medical TestingYLC-01AMask Airflow Resistance Tester->
WAAsk an engineer