- Pharmaceutical bottle caps
- Beverage bottle caps
- Mineral-water caps
- Oil and cosmetic closures
Cap Torque Tester
Measure opening and tightening torque on bottle and closure assemblies.
A digital cap torque tester for opening and tightening measurements on pharmaceutical, beverage, food, cosmetic and general bottle closures.
Included reference configuration: One NLY-01 manually operated digital cap-torque tester with the standard 20 Nm range and container clamp. Higher-capacity sensors and special closure fixtures are quoted separately.
Delivery basis & quotation terms
Budgetary reference for one system, FCA Jinan, China (Incoterms 2020). International freight, insurance, import duties/taxes, overseas on-site service and optional upgrades are excluded. The itemized written quotation confirms the final configuration and total. Existing project quotations retain their own terms and validity.

Workflow and key features
The NLY-01 clamps the container and records the peak torque required to open or tighten its closure. Objective torque data helps balance leak resistance, tamper performance and user openability.
- Measures both opening and tightening torque
- Adjustable fixtures cover multiple bottle and cap geometries
- Peak capture replaces subjective hand-tightening checks
- Useful for closure development, line setup and routine production sampling
- Range and fixture are selected for the expected torque and package size
Reference configuration
Published values describe the referenced standard configuration. The formal quotation confirms the selected range, fixtures, utilities, method edition and supplied documentation.
- Torque range
- 0-20 Nm standard; 40 Nm and 50 Nm optional
- Accuracy
- 0.3% FS
- Torque resolution
- 0.001 Nm
- Container clamping range
- 5-200 mm diameter
- Statistical sample count
- 0-100
- Power
- 40 W
- Machine dimensions
- 350 x 305 x 300 mm (L x W x H)
- Net weight
- 17 kg
- Electrical supply
- AC 220 V, 50 Hz
Test-method referencesWorkflow references, not a certification claim3 references +
These references identify workflows described for this model. The formal quotation confirms the exact edition, fixtures, software, accessories and verification documents supplied for the selected configuration.
- GB/T 17876-2010
- BB/T 0025-2004
- ASTM D3474-2018
- Material structure and thickness
- Sample dimensions
- Required test method
- Expected force, pressure or barrier range
The quoted configuration remains the controlling specification.
Published values describe the referenced standard configuration. The formal quotation confirms the selected range, fixtures, utilities, method edition and supplied documentation. Delivery scope, warranty, lead time, calibration evidence and overseas service are stated in the formal offer.