Linear Thermal Expansion Coefficient Tester
Characterize expansion and contraction of glass and related materials during heating.
An automated laser-displacement system for measuring linear thermal expansion and contraction of pharmaceutical glass and related materials at elevated temperature.

Workflow and key features
The XRC-800A controls the thermal program, captures specimen displacement with a laser sensor and calculates expansion results and curves in software. Its large test space and integrated cooling are designed to improve consistency and reduce the interval between tests.
- Automatic chamber closure and test sequence reduce operator variation
- Laser displacement measurement supports dynamic expansion analysis
- Integrated cooling shortens turnaround between high-temperature tests
- Software calculates expansion coefficients and records temperature-displacement curves
- Local storage, audit trail and export functions support GMP-oriented data control
Reference configuration
Published values describe the referenced standard configuration. The formal quotation confirms the selected range, fixtures, utilities, method edition and supplied documentation.
- Maximum temperature
- Ambient to 400 deg C
- Displacement range
- 0-5 mm
- Heating rate
- 1-30 deg C/min
- Displacement resolution
- 0.0001 mm
- Specimen length
- 10-180 mm; spacer adjustment required
- System accuracy class
- Class 0.2
- Operating environment
- Ambient to 40 deg C; RH <=60%
- Machine dimensions
- 800 x 770 x 1390 mm (L x W x H)
- Circuit-breaker rating
- 20-25 A
- Power
- 1.5-5 kW
- Weight
- 250 kg
- Electrical supply
- AC 220 V, 50 Hz
Test-method referencesWorkflow references, not a certification claim1 references +
These references identify workflows described for this model. The formal quotation confirms the exact edition, fixtures, software, accessories and verification documents supplied for the selected configuration.
- YBB00202003-2015
- Container type and drawing
- Sample dimensions and quantity
- Required test method
- Target load, pressure or thermal profile
The quoted configuration remains the controlling specification.
Published values describe the referenced standard configuration. The formal quotation confirms the selected range, fixtures, utilities, method edition and supplied documentation. Delivery scope, warranty, lead time, calibration evidence and overseas service are stated in the formal offer.