<- Pharmaceutical & Medical TestingNeedle Mechanics / 35ZGX-01A

Medical Needle Stiffness Tester

Evaluate bending stiffness of sterile injection-needle tubing.

A medical needle stiffness tester for measuring the bending resistance of sterile injection-needle tubing.

Reference unit price / AvailabilityUSD 4,500 per system / In stock
ZGX-01A Medical Needle Stiffness Tester
01 / Application

Workflow and key features

The ZGX-01A supports the needle at defined spacing, applies a controlled load or displacement and records deflection. It helps manufacturers verify that tubing is stiff enough for intended use without relying on visual judgment.

  • Defined support and loading geometry for needle-tube stiffness
  • Quantified deflection supports batch and supplier comparison
  • Applicable to injection needles and compatible rigid stainless-steel tubing
  • Controlled motion improves repeatability over manual bending checks
  • Fixture spacing and needle range are selected against the required method
02 / Public technical data

Reference configuration

Published values describe the referenced standard configuration. The formal quotation confirms the selected range, fixtures, utilities, method edition and supplied documentation.

Set load
0.6-60 N
Accuracy
+/-0.1 N
Travel
500 mm
Loading speed at setpoint
1 mm/min
Support span
5-50 mm
Machine dimensions
420 x 410 x 1020 mm
Net weight
65 kg
Electrical supply
AC 220 V, 50 Hz
Test-method referencesWorkflow references, not a certification claim3 references

These references identify workflows described for this model. The formal quotation confirms the exact edition, fixtures, software, accessories and verification documents supplied for the selected configuration.

  • ISO 9626:2016
  • GB 18457-2015
  • GB 15811-2016
Typical materials
  • Injection needles
  • Rigid stainless-steel tubing
  • Medical needle components
  • Prepared tubing samples
Send with your inquiry
  • Device or protective-article type
  • Required test method
  • Challenge conditions or expected force range
  • Sample dimensions and quantity
Configuration boundary

The quoted configuration remains the controlling specification.

Published values describe the referenced standard configuration. The formal quotation confirms the selected range, fixtures, utilities, method edition and supplied documentation. Delivery scope, warranty, lead time, calibration evidence and overseas service are stated in the formal offer.